top of page
walk-in salt spray chamber battery
AdobeStock_139727050.jpeg
AdobeStock_144193160.jpeg
DeepFreeze.jpeg
AdobeStock_408801758.jpeg
AdobeStock_407283749.jpeg

Corrosion testing device
Battery test

walk-in salt spray chamber battery
60003230-JUMO-Safety temperature limiter-70-to-130-C-Telecommunication-2000-mm-60003230-1_6

Security Package I

  • electropneumatic door locking mechanism

  • independent safety temperature limiters

Achievable Hazard Level: 0-3

Note: If the gas or liquid (electrolyte) escaping from the cell is flammable, then Hazard Level 5 applies.

Untitled Design (3).png

Security Package II

  • electropneumatic door locking mechanism

  • independent safety temperature limiters

  • Pressure relief via reversible pneumatic valve

Achievable Hazard Level: 0-4

Note: If the gas or liquid (electrolyte) escaping from the cell is flammable, then Hazard Level 5 applies.

Untitled Design (2).png

Security Package III

  • electropneumatic door locking mechanism

  • independent safety temperature limiters

  • Pressure relief via reversible pneumatic valve

  • Fire detection through carbon monoxide measurement

  • Flushing system CO2/ N2 / LN2 (Optional: Water sprinkler)

Achievable Hazard Level: 0-5

KE2.png

Security Package IV

  • electropneumatic door locking mechanism

  • independent safety temperature limiters

  • Pressure relief via reversible pneumatic valve

  • Fire detection through carbon monoxide measurement

  • Flushing system CO2/ N2 / LN2 (Optional: Water sprinkler)

  • Overpressure relief via rupture disc

 

Achievable Hazard Level: 0-6 (7)

Note: Level 7 may only be operated with a very small risk, as a tolerable residual risk.

Salt spray systems for battery testing and more

Quality assurance, for example for batteries used in electric vehicles, is becoming increasingly important. The safety of people and the environment plays a crucial role here. To guarantee long-term safety, the batteries must be tested under a wide variety of weather conditions.

We offer a corrosion testing system for battery testing that can meet various testing standards. Through precisely tailored safety measures and close customer consultation, we can find a solution for all customer requirements. All existing Hazard Levels (HL) 0-7 can be implemented.

Simply contact us to see which testing standards are feasible and what requirements are needed for your project.

Testing standards

The following list provides a small selection of the testing standards that can be implemented. Is the testing standard you need not included? Contact us and we will find a suitable solution.

Regarding the testing standards

DIN EN ISO 9227 NSS/AASS/CASS

DIN EN ISO 6270-2 CH/AT/AHT

DIN EN ISO 11997-1 and 2

PV 1210

PV 1078

DIN EN 60068-2-52 severity level 1-6

bottom of page